Guide to individual parts -
Abridged instructions -
Opening the camera back -
Inserting the film -
Closing the camera back -
Preparing for the exposure -
Setting the film speed -
Setting the exposure speed -
Setting the diaphragm numeral -
Automatic Exposure Control -
Metering at full aperture with shutter speed preselected -
Metering at full aperture with diaphragm stop preselected -
Metering at taking aperture with shutter speed preselected -
Metering at taking aperture with pre-set diaphragm -
Measuring range of the PRAKTICA LLC -
Focusing -
Releasing and cocking the shutter -
Delayed-action release -
Changing the film -
Exchanging lenses -
Flash exposures -
Exchanging the power source -
Maintenance and care
|
We are very pleased that you have chosen the high quality PRAKTICA LLC, and we wish you every success in working with this modern reflex camera. Before using your camera, however, we would request you to read these Instructions for Use very carefully. This will help you to avoid errors or trouble caused by wrong handling. |
|
1. Knob for setting the shutter speeds
2. Cocking lever for delayed-action release
3. Delayed-action release knob
4. Shutter release
5. Rewind knob
|
|
6. Rewind crank
7. Accessory shoe
8. Center flash contact
9. Exposure speed index
10. Film speed scales
11. Film speed index
12. Rapid cocking lever
13. Exposure counter
14. Distance setting ring
15. Diaphragm setting ring
16. Selector ring for automatic exposure control
17. Symbols for measuring at full aperture or taking aperture
|
|
18. Rewind catch
19. Cartridge chamber
20. Supporting piece
21. Marking point for inserting the film
22. Film transport sprocket
23. Wire bracket
24. Metal-blade focal - plane shutter
25. Ocular mount with fitting for accessories
|
|
26. Rewind release knob
27. Battery compartment with PX 21 battery
28. Tripod socket
29. Take-up spool
30. Manual stop down key
31. Depth-of-field scale
|
|
Abridged instructions
Opening the camera back: Pull out rewind knob (5) as far as it will go.
Inserting the film: Place film cartridge into cartridge chamber (19), push in rewind knob (5). Slant the beginning of the film and push it from above as far as it will go underneath the supporting piece (20) and over the transport sprocket (22). Bring the beginning of the film strip onto the core of the take-up spool (29) and to its green marking point (21).
Wire bracket (23) of the take-up spool must not stand upwards.
Preparing for the exposure:
Actuate rapid cocking lever (12) and shutter release (4) until exposure counter (13) stands on number "1".
Setting the film speed:
Lift the knurled ring of speed setting knob (1) and rotate it until the speed value of the film in the camera stands opposite the film speed index (11).
Setting the exposure speed:
Rotate speed setting knob (1) until the desired speed numeral stands opposite the orange-colored triangle (9) on the cover plate of the camera.
Setting the diaphragm numeral:
Rotate diaphragm setting ring (15) on the lens mount to bring the desired diaphragm numeral against the red index mark.
Automatic exposure control:
When using lenses permitting electric transmission of the diaphragm values, set the selector ring (16) to the OPEN CIRCLE symbol = measuring at full aperture. For lenses without electric transmission set the selector ring to the CLOSED CIRCLE symbol = measuring with the lens at taking aperture!
Preselect either the shutter speed or the aperture. Depress shutter release (4) till you feel the pressure point, At the same time rotate either the diaphragm setting ring (15) or the speed setting knob (1) till the meter needle is centered in the circular mark in the viewfinder field. In connection with the taking aperture of lenses with automatic diaphragm control, the stop down key (30) has to be depressed when meter reading is taken or the engaging kind selection lever of the 50 mm f/1.8 Pancolar lens, which is designed for electric transmission of diaphragm values, has to be actuated downwards to the camera battery.
Focusing:
Rotate distance setting ring (14) until the image in the microprism screen or in the ground glass field appears perfectly sharp.
Releasing and cocking the shutter:
Depress shutter release (4) to beyond the pressure point. After the shutter has run down a signal appears in the left-hand side of the viewfinder. Swing cocking lever (12) around as far as it will go and return it into its initial position.
Delayed action release:
Swing delayed-action cocking lever (2) upwards either before or after cocking the shutter. Depress knob (3) to release the delayed-action mechanism.
Changing the film:
After the last exposure, depress rewind release knob (26), swing out rewind crank (6) and turn it in direction of arrow to rewind the film. Open the camera back and remove the cartridge.
|
|
Opening the camera
Pull rewind knob (5) upwards until you feel hard resistance. The camera back is thus unlocked and can be opened. The exposure counter (13) will automatically jump to zero position. |
|
 |
 |
Inserting the film
Any type of perforated 35 mm film in commercially available standard cartridges may be used. The cartridges contain film lengths for 36, 20 or 12 exposures in the 24 x 36 mm format. To make sure that no light enters the slit of the cartridge the film should not be loaded in direct sunlight. The shade of your own body will suffice.
By having pulled out the rewind knob (5) to open the camera back you have withdrawn the rewind-catch (18) from the cartridge chamber (19), so that you can now place the cartridge into the cartridge chamber.
Push the rewind knob, with slight backward and forward movements, right back into the camera. The rewind catch will engage in the core of the cartridge.
Push the beginning of the film projecting out of the cartridge slit from above as far as it will go underneath the supporting piece (23) arranged above the transport sprocket (22). The beginning of the film strip must now lie on the core of the take-up spool (29) and meet the green marking point (25).
The wire bracket (23) of the take-up spool must not stand upwards. Should this happen to be the case the knurled flange of the spool has to be turned to bring the bracket wires to their lateral position.
|
|
Closing the back
Press the camera back firmly on to the camera body. It locks automatically. |
|
Preparing for the exposure
The rapid wind lever (12) has an idle stroke of about 15°, so that it can be moved from its rest position into that of readiness for action, and can thus be easily grasped - a great advantage especially in serial shots.
Swing the cocking lever around as far as it will go, return it, and depress shutter release knob (4). Repeat these operations and then cock the shutter once more. The automatic exposure counter (13) now stands on number "1". Special setting of the exposure counter is not necessary since it starts working automatically when the camera back is closed. |
To avoid inadvertent tripping, the shutter release (4) is provided with a locking device. The release mechanism is locked when the red dots on the knob and on the outer ring meet. The mechanism is unlocked by rotation of the knob through 90°. |
|
Setting the film speed
To set the film speed value for the automatic exposure control, the knurled ring of the speed setting knob (1) has to be lifted and rotated until the speed value of the film loaded (DIN or ASA) stands opposite the white index (11). When lowered, the knurled ring clicks in at the selected film speed numeral.
|
|
Setting the exposure speed
The metal-blade focal-plane shutter can be set for exposure speeds range from 1 sec. to 1/1000 sec.
When set on "B" the shutter remains open as long as the release knob (4) is being depressed. For exposures of a longer duration a cable release with locking device should be used which can be screwed into the thread in the body release knob. Regarding exposure speeds in connection with flash units please refer to Flash exposures.
The orange-colored numerals on the shutter-speed setting knob (1) stand for slow speed exposures from 1 sec. to 1/15 sec. which require the use of a tripod. The white numerals indicate the values for instantaneous shots from 1/30 sec. to 1/1000 sec.
The exposure speeds are set by rotating knob (1) until the desired numeral coincides with the orange-colored triangle (9) on the cover plate of the camera. Please note that the knurled ring of the setting knob must not be lifted up since this would alter the film speed setting and cause the automatic exposure system in the PRAKTICA LLC to give incorrect results.
The exposure speeds can be set either before or after the shutter has been cocked. The setting knob clicks in at every numeral. Intermediate values are not adjustable.
|
|
Setting the diaphragm numeral
On the lenses with automatic pressure diaphragm (APD) only the desired aperture numeral on the diaphragm setting ring (15) has to be brought to meet the appropriate index on the lens mount. The diaphragm thus remains fully open at first and closes down to the preselected value when the shutter release is depressed.
The automatic diaphragm control mechanism in the PRAKTICA LLC causes the pressure diaphragm to function as an automatic spring diaphragm. Regardless of the speed with which the shutter release (4) is depressed, the diaphragm will spring to the preselected value and then open again immediately after the shutter has run down.
|
For checking the depth of field in the viewfinder image, most lenses can be stopped down, before the exposure is made, to the preselected value or to the value determined by the exposure meter by means of a manually operable key (30) on the lens mount.
The 50 mm f/1.8 Pancolar lens with electric transmission of diaphragm values has a kind selection lever opposite the lens mount instead of the stop down key. With the lever in the upper position the diaphragm operates as an automatic spring diaphragm whereas in its lower position, depressed towards the camera bottom, the automatic diaphragm control mechanism is disengaged. The diaphragm acts as a click stop and closes according to the value preset on the diaphragm ring. |
|
Automatic Exposure Control
The newly devised automatic exposure system in the PRAKTICA LLC makes it possible, by means of the electric transmission of the diaphragm values, to take the meter readings with the photographic lens at full aperture, so that the viewfinder image remains at its maximum brightness. The lenses arranged for metering at full aperture are recognizable by three resilient contact pins visible at the rear end of the barrels, which join the contact paths on the camera.
|
But it is also possible to use the well-known lenses of the PRAKTICA family without automatic diaphragm control. In this case, metering is performed with the lens stopped down to taking aperture. The finder image will thus be somewhat darker, according to the aperture selected, or determined by the exposure meter.
Whether your lens is at full aperture or stopped down, you have in either case, two methods of metering from which to choose:
a) You preselect the shutter speed and adjust the aperture to center the meter needle, or
b) You preselect a certain aperture and adjust the shutter speed to center the meter needle.
The first method is applied, e.g., if movement of the object requires a certain exposure speed, whereas the second method will be preferred if a specific aperture has to be preselected to achieve the necessary depth of field.
|
|
Metering at full aperture with shutter speed preselected
Set the index of selector (16) which, as a knurled ring, encircles the rewind knob, to coincide with the empty circle symbol. Preselect the exposure speed by actuating knob (1). Depress shutter release (4) till you feel the pressure point and rotate diaphragm setting ring (15) on the lens mount till the meter needle visible in the viewfinder field is centered in the circular mark.
If on the rotation of the diaphragm setting ring or the exposure speed setting knob the meter needle deflects no more, replace the power source (see section: Exchanging the power source).
|
|
Metering at full aperture with diaphragm stop preselected
Set selector ring (16) to the open cirlce symbol. Move the diaphragm setting ring (15) on the lens mount to a stop corresponding to the taking conditions. Depress shutter release (4) till you feel the pressure point and rotate the exposure-speed setting knob (1) till the meter needle is centered in the circular mark. The exposure speed knob must always be set to click-stops and not to intermediate values. Should this not bring the meter needle precisely to the center of the circular mark, the diaphragm ring has to be moved for fine adjustment. The diaphragm ring can be set to intermediate values between the click-stops.
|
|
Metering at taking aperture with shutter speed preselected
This method is employed in connection with lenses not permitting electric transmission of the diaphragm values. Move selector ring (16) to the full circle symbol. Preselect the shutter speed adjust the diaphragm ring to center the meter needle as described above. On lenses with automatic pressure diaphragm the stop down key (30) on the lens mount has to be depressed while the meter reading is taken.
The 50 mm f/1.8 Pancolar without electric transmission of the diaphragm values is provided with a kind selection lever by which you can change over from automatic diaphragm control to manual operating (please see Setting the diaphragm numeral). For meter reading this lever must be in its lowermost position so that the diaphragm acts as click stop. As soon as the lever is returned into its upper position, metering is performed automatically again. |
|
Metering at taking aperture with pre-set diaphragm
To be employed with lenses not permitting electric transmission of the diaphragm values selector ring (16) stands on the full circle symbol. Preselect aperture on diaphragm ring of lens mount and adjust shutter speed setting knob to center meter needle. Pay attention to click-stops and fine adjustment by means of diaphragm ring. Here, too, the shutter release has to be actuated up to the perceptible pressure point.
If lenses without automatic diaphragm, i.e. lenses with pre-set or plain diaphragm, are being used for metering at taking aperture, the lens remains stopped down until the shutter is released. It is, therefore, advisable to focus with the lens wide open before taking the meter reading.
Owing to the construction of their barrels, some of the older types of lenses protrude so far into the interior of the camera body as to impede the functioning of the swing mechanism for the automatic diaphragm. Thus, mirror and shutter cannot work. These lenses cannot be used in the PRAKTICA LLC. They are recognizable by the structure of their barrels, as may be seen from the illustration above.
|
|
Measuring range of the PRAKTICA LLC
If the luminous density of the object to be photographed is very low, the meter needle, even at the smallest diaphragm numeral -- e.g. 1.4 -- and a slower shutter speed, cannot be centered within the circular mark. In fact, the selection of yet longer exposure periods will disconnect the automatic exposure system, so that the meter needle will swing downwards to its stop point. When lighting conditions become more favorable again, a shorter exposure time has to be set before the automatic exposure system will recommence functioning.
The table shows within which range of speeds the automatic system works in connection with the various film speed settings.
|
| Speed of film |
|
| DIN |
ASA |
Exposure-speed |
| 12 |
12 |
1 sec. to 1/1000 sec. |
| 15 |
25 |
1 sec. to 1/1000 sec. |
| 18 |
50 |
1 sec. to 1/1000 sec. |
| 21 |
100 |
1/2 sec. to 1/1000 sec. |
| 24 |
200 |
1/4 sec. to 1/1000 sec. |
| 27 |
400 |
1/8 sec. to 1/1000 sec. |
| 30 |
800 |
1/15 sec. to 1/1000 sec. |
| 33 |
1600 |
1/30 sec. to 1/1000 sec. |
|
|
Focusing
To brighten up the image, the prism viewfinder of the PRAKTICA LLC is fitted with a Fresnel lens, in the center of which are the two focusing systems:
the microprism screen right in the middle and the circular ground glass area surrounding it.
Focusing is performed by rotating the distance setting ring (14) on the taking lens. To achieve utmost definition when using lenses with pre-set diaphragm or simple diaphragm adjustment, it is advisable to focus with the lens set to the smallest diaphragm numeral (full aperture).
|
Focusing on the microprism screen
The image in the microprism screen is in correct focus as soon as it appears clear and free from fuzziness. It is out of focus if it looks fuzzy and crumbles into screen elements. The microprism screen is usually employed for focusing if the subject to be photographed is in resting position or only slightly moving.
Focusing on the circular ground glass area
The ground glass area is used for focusing if there is more movement in the scene. Also this kind of setting is often most appropriate in macrophotography or photomicrography as well as on lenses with a small relative aperture (diaphragm numeral higher than 4).
The ground Fresnel section of the viewfinder is not meant to be used for focusing.
Depth-of-field indication
The depth of field is determined by means of the depth-of field scale (31) arranged on the right and left of the red index on the lens mount.
While the value of the camera-to-subject distance figure stands opposite the distance mark, the limits of the range of definition can be read from the distance scale above the numerals on the depth-of-field scale, which latter are equivalent to the diaphragm numerals of the lens. As an example, the illustration shows a zone of sharpness from 2 m to 5 m (7 ft. to 16 ft.) for a distance setting of 3 m (10 ft.) and an f/8 aperture.
When the manual stop down key is depressed or the diaphragm selection lever of the 50 mm f/1.8 Pancolar is in its lowermost position, you will be able to judge depth of definition in the finder image.
Persons with defective eyesight may work without their spectacles on by having a corrective lens corresponding to their long-distance glasses fitted into the eye cup which is then attached to the ocular mount.
|
For infrared exposures the focusing point has to be slightly modified. By rotation of distance setting ring (14), the distance reading which, after focusing, stands opposite the distance mark, has to be moved to meet the infrared dot next to that mark. Thus, the image produced by the infrared rays is brought into correct in relation to the film |
|
Releasing and cocking the shutter
Before releasing the shutter, please note the following:
1. Make sure that the shutter release is unlocked (see Preparing for the exposure)
2. If the signal is visible in the left side of the viewfinder, the camera is not ready for exposing. The shutter has to be cocked!
3. For exposure speeds slower than 1/30 sec. a tripod and a cable release should be used.
|
We advise you to hold your PRAKTICA LLC so that it lies firmly in both hands and you are able to actuate the shutter release (4) comfortably.
Depress the shutter release steadily -- never with a jerk past the soft-running limit, where the automatic exposure system is switched in, until the shutter runs down.
After the exposure, the signal on the left side of the viewfinder image becomes visible again, a sign that the shutter has to be cocked.
|
|
Delayed-action release
The delayed-action mechanism is cocked by moving lever (2) upwards as far as it will go. By means of pressure on knob (3) it will start and after about 10 seconds the shutter is released. The delayed-action mechanism may be tensioned either before or after the shutter is cocked. Also, the shutter can be released in the usual manner by means of release knob (4), even if the delayed-action device is tensioned.
|
|
Changing the film
When the exposure counter (13) indicates the maximum number of frames obtainable with the film in the camera (12, 20 or 36 exposures) the film has to be rewound and taken out of the camera.
Depress rewind release knob (26) in the base plate of the camera It will remain locked in this position. Unfold rewind crank (6) out of rewind knob (5) and rotate it, not too quickly, in the direction of the arrow. Rewinding at too great a speed may cause electrostatic charge and static on the film.
As rewinding is completed, greater resistance becomes noticeable until the film is disengaged from the take-up spool. After this, the crank turns quite easily.
Fold the rewind crank back into the knob and pull the knob upwards as far as it will go. The camera back is thus unlocked and can be opened. Remove the cartridge with the exposed film from the cartridge chamber. Loading a new film, and subsequent cocking of the shutter, cause the rewind knob (26) to spring back automatically out of its click-stop position.
Should you have attempted to expose more frames than the number marked on your film packet, the cocking lever might, at the end of the film, get jammed so that it cannot be swung around completely. Do not, in such a case, use force, as this might cause damage to the perforation of the film, or the end of the film might slip off the spool inside the cartridge. Rewinding would then be impossible.
If the cocking lever - as described above - has not been fully tensioned, this must be completed, and the shutter released, after rewinding and removing the exposed film and before inserting a new one.
 |
 |
|
|
Exchanging lenses
The standard lens of the PRAKTICA LLC can easily be replaced by lenses of other focal lengths. You take hold of the lens body, as shown in the illustration below, and turn it in an anti-clockwise direction. The exchange lens is inserted accordingly and screwed tight.
For exposure measurement at the widest lens aperture in the PRAKTICA LLC, lenses permitting electric transmission of the diaphragm values are employed. The name of the lens is added by "electric". Furthermore, these lenses are recognizable by three contact pins visible at the rear end of the barrels. But you may also use the ordinary PRAKTICA lenses with this camera, in which case metering has to be performed with the lens stopped down to taking aperture.
Because of their structural design, some of the older types of lenses cannot be used with the PRAKTICA LLC. (For details please refer to Automatic exposure control).
List of interchangeable lenses:
1. Lenses permitting electric transmission of diaphragm values
aus Jena Pancolar - 50 mm f/1.8 - APD
PENTACON electric - 50 mm f/1.8 - APD
PENTACON electric - 29 mm f/2.8 - APD
PENTACON electric - 100 mm f/2.8 - APD
PENTACON electric - 135 mm f/2.8 - APD
2. Lenses not permitting electric transmission of diaphragm values
aus Jena Flektogon - 20 mm f/4 - APD
aus Jena Flektogon - 35 mm f/2.8 - APD
PENTACON auto - 50 mm f/1.8 - APD
aus Jena Pancolar - 50 mm f/1.8 - APD
aus Jena T - 50 mm f/2.8 - APD
PENTACON - 135 mm f/2.8 - PD
aus Jena S - 180 mm f/2.8 - APD
PENTACON - 200 mm f/4 - PD
PENTACON - 300 mm f/4 - PD
PENTACON - 500 mm f/5.6 - PD
aus Jena catoptric lens - 1000 mm f/5.6 - without diaphragm
APD = automatic pressure
PD = pre-set diaphragm
For the rest of the interchangeable lenses, go to: M42 lens list.
|
|
Flash exposures
The shutter of the PRAKTICA LLC is designed for synchronization with flash bulbs and electronic flash units.
When the flash unit is attached to the camera, the electric connection between camera and unit is automatically effected by means of the center contact (8) in accessory shoe (7). No synchronization cable is required. Modern flashbulb and electronic units are equipped for this purpose with a suitable co-operation contact.
For the use of flash units fitted with a synchronizing cable, an adapter piece with flash socket to accept the cable plug has to be pushed on to the accessory shoe of the PRAKTICA LLC.
|
Flash bulb exposures
In connection with bulbs for short flash duration, the shutter has to be set for a speed of 1/30 sec. -- marked by the lamp symbol -- or slower. The ignition circuit is closed only as long as the shutter runs down and is open after the shutter has terminated running-down and during the tensioning procedure, so that flash bulbs can be exchanged also before the shutter is cocked.
Electronic flash exposures owing to the extremely rapid travel of the curtains in the metal-blade focal-plane shutter, synchronization up to a shutter speed of about 1/125 sec. is made possible. The knob for setting the shutter speed has to be moved to the flash symbol setting next to "B".
The guide number
The diaphragm numeral to be set on the lens mount for flash exposures can be found with the aid of the "guide number". Manufacturers of bulbs and electronic flash units give these guide numbers on the wrappings or in the instructions for use as required for the various sensitivity grades of the negative material. The correct aperture is determined by dividing the guide number for the flash in use by the flash-to-subject distance figure (in metres). Formula for the flash unit is attached to the accessory shoe of the camera.
|
|
Exchanging the power source
The exposure meter system is powered by a Mallory battery of the PX 21 type.
The battery compartment (27) is on the under side of the camera. It is opened by lifting the plastic lid by means of its handle piece.
When inserting the battery, press its bottom plate (positive pole) against the spring contact (also marked +), while at the same time tipping it into the battery compartment.
To close the battery compartment, attach the side of the lid opposite the handle to the corresponding side of the compartment and depress the lid on the handle side until it clicks in.
Owing to the low consumption of current during the period of reading, with normal use of the camera, the battery should be exchanged after about two years, only. |
|
|
|
Maintenance and care
The PRAKTICA LLC is a high quality precision instrument. Perfect functioning of the camera depends very largely on proper handling and careful maintenance.
The camera must, above all, be protected against shock and impact, dust and moisture. That is why the everyday case should be used wherever possible.
From time to time the cartridge chamber and spool chamber, also the film track and camera back with film pressure plate must be cleaned with a soft brush. But be careful not to exert pressure on the steel blades of the shutter nor to touch them with your fingers.
Neither should the optical parts (lens, eyepiece of viewfinder, mirror) be touched with the fingers. Should this have happened accidentally, any fingerprints must be removed immediately with a soft cotton cloth after a soft brush has been used to remove any possible dust. The mirror should be dusted only in urgent cases with a very soft brush.
Never clean, or by any means apply abrasives to the precious metal pins on the lenses, the means of electrically transmitting the diaphragm values, or to the three precious-metal coated contact paths in the camera. The contact points are automatically cleaned in the process of exchanging lenses. But also here, any dust which may have accumulated has to be removed with a soft brush.
If due to the battery in the battery chamber a thin white layer has deposited, the latter can be removed with a soft cloth.
Do not interfere with the mechanism of the camera. Repair work should be carried out only by one of our special Repair Workshops.
|